Get complete information related to latest Fuse Base Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Base Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Base Tenders.
Tender For supply of spare of lt vfd at hurl sindri on oem basis - dual temperature transmitter, filter capacitor for sine wave filter, current transformer ratio - 100/1a, vfd control device, vfd power device, hrc fuse link bs type, fuse holders & isolating link, hrc fuse bs type, fuse-link rating-80a, ac 690 v., fusebase nh din type, "6"" output filter ral 7035 size 6 incfan failure and temp detection unitiop (intelligent operator panel)power contactor rating-45a, 230v ac", "sine wave filter reactor rating -22kwpanel fanmulti-function meter (mfm)32-50 a, thermal overload relay""", circuit breaker with electronic trip, panel door mounted rotary op. handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, 5a, d series ac drm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs-4-20ma, motor restart timer, green push button & contact block, red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block., yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For supply of 40 amps hrc fuse for a3 fuse link bolted connections, rated voltage upto 660v ac, breaking capacity : 80ka, class of operation: gg/gm. conforming to is specification section -ii of is: 13703 (part2/sec-2), 1993 along with suitable fusebase of size a3, 40a as per rdso's drawing rdso/pe/sk/tl/0096-2006 (rev.0). as per drg.no. is: 13703(part 2/sec 2), 1993 and as per rdso's dr [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of specs as per pdf documents , compressor for 1 point 5 ton specs as per pdf documents , compressor for refrigeraor specs as per pdf documents , compressor for refrigerator specs as per pdf documents , contactor for star delta starter specs as per pdf documents , contactor ml 3 or 4 pole suitable for 60 hp electric motor starter , coolant for dg set , copper lugs long barrel specs as per pdf documents , copper lugs long barrel size 150 sqm make dowells or action or ascon , copper lugs long barrel size 240 sqm make dowells or action or ascon , copper lugs size 16 sqm make dowells or action or ascon , copper lugs size 25 sqm make dowells or action or ascon , copper lugs size 35 sqm make dowells or action or ascon , copper lugs size 50 sqm make dowells or action or ascon , copper lugs size 95 sqm make dowells or action or ascon , copper lugs size long barrel 100 mm 120 sqm make dowells or action or ascon , copper lugs size long barrel 100mm 300 sqm make dowells or action , decorative post top lantern for specs as per pdf documents , epr ht insulation tape 50 mm wide 09 m long , fan blade for desert cooler 450 mm , fuse wire of cap 50 amp , geyser indicating lamp as per sample , heating element for geyser specs as per pdf documents , heating element geyser 2 kw make usha , isolator fp 100 amps make indoasian or havells or standard , isolator fp 63 amps make indoasian or havells or standard , louver shutter for 250 by 300 mm exhaust fan as per sample , louver shutter for 400 by 450 mm exhaust fan as per sample , male female contact specs as per pdf documents , metal clad industrial plug specs as per pdf documents , over load relay for water cooler 40 by 80 ltrs , pvc casing caping 20 mm specs as per pdf documents , pvc casing caping 25 mm specs as per pdf documents , pvc conduit pipe 20 mm 2 mm thick specs as per pdf documents , pvc conduit pipe 25 mm 2 mm thick specs as per pdf documents , pvc insulated aluminium conductor specs as per pdf documents , pvc insulation tape 25 mm x 25 mtr make steel grip , refrigerant gas r 134 a 450 ml bottle , relay over load for water cooler 60 or 120 ltrs , relay starting with olp for refrigerator , royal plug 50 mm long pack of 100 , socket outlet 5 amp make bajaj or philips or cg or havells , sumbersible pump for desert cooler , syphon assy for geyser 25 ltrs make usha or havells , teflon tape for plumber as per sample , termination kit 50 sqmm 3 point 5 core , thermostat for geyser specs as per pdf documents , tinned copper flexible jumper 11 kv for god 200 amp set of 3 , batten holder make anchor or c and s or ge lighting or havells or cg , ceiling rose 3 terminals make anchor or philips or havels , isolator 40 amp 4 pole make havels or c and s standard , tape insulation 20 mm x 20 mtr long make steel grip or anchor , thermo state for geyser make usha or havels 2a batten lamp holder jumbo fancy type 230v 50hz, capacitor 3 point 15 mfd make usha or havells or bajaj, capacitor for ceiling fan specs as per pdf documents, copper alloy thimbles 1 sqmm pin type pkt of 200 nos, copper alloy thimbles 1 point 5 sqmm pin type pkt of 200 nos, copper alloy thimbles 4 sqmm pin type pkt of 200 nos, fuse wire 60 amp or 100 amp or 200 amp, geyser heating element triangularspecs as per pdf documents, lead ring suitable for 150 mm dia , lead ring suitable for 200 mm dia , lead ring suitable for 80 mm dia , pvc insulation tape of size 20 mm x 25 mtr, submersible pump suitable specs as per pdf documents, tinned copper fuse wire 10 amp, tinned copper fuse wire 20 amp, tinned copper fuse wire 30 amp, tinned copper fuse wire 60 amp, aluminium lugs //bid details 2 / 73
Tender For corrigendum : supply of high voltage fusebase of rating 4a, 1.2kv similar to siba make part no.7103401 suitable for cylindrical type fuse of size 8x50 mm for voltage control of lhb ac coaches. acceptable makes: as per rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1) i.e ferraz, siba, eaton, bussmann, wohner only. [ warranty period: 30 months after the date of delivery ]
Tender For supply of hrc fuse 16amps/100v dc bottle type consists of (1) fusebase. (2) fuse link. (3) fusecarrier. (4) gauge piece. (5) collar ring to clw specfication clw/es/f8 alt-e & to clw drg.no. clw/es/sk-1/f8 type a16. (authorised dealers should enclose the original authorisation letter along with their tender) [ warranty period: 30 months after the date of delivery ]